Selection Guide

Choose a model by boosting level, duty point, power supply and pipe size

Four steps decide most selections: the duty point, the water source, the power supply, and the control and power stage. The guide covers flows from 25 L/min to 500 L/min and heads from 25 m to 75 m, plus pipeline boosting for DC duty.

  1. 1

    Duty point — required head = lifting height + pipework loss + target outlet pressure (2 bar ≈ 20 m); match to a boosting level.

  2. 2

    Water source — mains or rooftop tank suits a standard booster; sump or well below the pump calls for self-priming ICP100F (8 m) or ICP106F (9 m); pH 6.5–8.5, particles below 0.2 mm; liquid max. 70 °C (55 °C for PYS-E/PYPZ-E), ambient max. 40 °C.

  3. 3

    Power supply — standard single-phase 170–250 V, 50/60 Hz (PB320EA 160–265 V); PYS-E/PYPZ-E customizable 110 V/60 Hz or 170–220 V.

  4. 4

    Control and power stage — ICP100F/ICP106F hold constant pressure across 10–30 m; 6 five-stage models (SPS-90, SPS90-3, SCS90P-3, SCS100P-3, ICP100A, ICP102-50); PB320EA has 3 power settings; dry-run, overload and fault alarm self-check.

By required flow and head

Maximum flow and maximum head from the 2026 catalog tables, with the boosting level each model belongs to. Select the model whose curve covers your duty point at the required outlet pressure.

Catalog duty range by model

ModelBoosting levelMaximum flowMaximum headPower rangePower supplyPipe sizeQuote
MT24-25Pipeline boosting25 L/min (1.5 m³/h)25 m (82 ft)0.2 kW (0.27 HP)DC 24 V15 mmRequest a Quote
ISC-200Pipeline boosting25 L/min (1.5 m³/h)25 m (82 ft)0.2 kW (0.27 HP)DC 24 V15 mmRequest a Quote
ISC2-200Pipeline boosting25 L/min (1.5 m³/h)25 m (82 ft)0.2 kW (0.27 HP)DC 24 V15 mmRequest a Quote
PB320EALevel 146 L/min (2.8 m³/h)32 m (105 ft)0.09 - 0.14 kW (3 power settings)160 - 265 V, 50/60 Hz3/4" (19 mm)Request a Quote
Z400Level 258 L/min (3.5 m³/h)50 m (164 ft)0.4 - 0.75 kW (0.55 - 1 HP)170 - 260 V, 50/60 Hz1" (25 mm)Request a Quote
SPS-90Level 160 L/min (3.6 m³/h)32 m (105 ft)0.18 - 0.38 kW (0.25 - 0.5 HP)170 - 250 V, 50/60 Hz3/4" (19 mm)Request a Quote
SPS90-3Level 170 L/min (4.2 m³/h)45 m (148 ft)0.27 - 0.58 kW (5-stage adjustable)170 - 250 V, 50/60 Hz1" (25 mm)Request a Quote
P800-3Level 272 L/min (4.3 m³/h)56 m (184 ft)0.75 kW (1.0 HP)170 - 260 V, 50/60 Hz1" (25 mm)Request a Quote
SCS90P-3Level 175 L/min (4.5 m³/h)45 m (148 ft)0.24 - 0.47 kW (5-stage adjustable)170 - 250 V, 50/60 Hz1" (25 mm)Request a Quote
PYS-ELevel 282 L/min (4.9 m³/h)56 m (184 ft)0.45 - 0.75 kW (0.6 - 1 HP)Customizable: 110 V / 60 Hz, or 170 - 220 V / 50 Hz or 60 Hz1" (25 mm)Request a Quote
PYPZ-ELevel 285 L/min (5.1 m³/h)55 m (180 ft)0.45 - 0.75 kW (0.6 - 1 HP)Customizable: 110 V / 60 Hz, or 170 - 220 V / 50 Hz or 60 Hz1" (25 mm)Request a Quote
ICP100FLevel 186 L/min (5.2 m³/h)38 m (125 ft)0.75 kW (1.0 HP)170 - 250 V, 50/60 Hz1" (25 mm)Request a Quote
ICP106FLevel 186 L/min (5.2 m³/h)42 m (138 ft)0.75 kW (1.0 HP)170 - 250 V, 50/60 Hz1" (25 mm)Request a Quote
ICP100ALevel 1102 L/min (6.1 m³/h)38 m (125 ft)0.3 - 0.75 kW (0.4 - 1 HP)170 - 250 V, 50/60 Hz1" (25 mm)Request a Quote
SCS100P-3Level 2165 L/min (9.9 m³/h)75 m (246 ft)0.55 - 1.5 kW (5-stage adjustable)170 - 260 V, 50/60 HzG 1.25" (32 mm)Request a Quote
SG95Level 2178 L/min (10.7 m³/h)73 m (240 ft)0.55 - 1.5 kW (0.75 - 2 HP)170 - 260 V, 50/60 Hz1" / 1.25" (25 / 32 mm)Request a Quote
ICP102-50Level 3500 L/min (30.0 m³/h)28 m (92 ft)0.35 - 1.5 kW (0.48 - 2 HP)170 - 250 V, 50/60 Hz2" (51 mm)Request a Quote

Swipe the table sideways to see every column.

170–250 V, 50/60 Hz standard, except PB320EA 160–265 V, SCS100P-3 / SG95 / Z400 / P800-3 170–260 V, P800/1500 motor 175–260 V; PYS-E/PYPZ-E customizable 110 V/60 Hz or 170–220 V; DC 24 V range with AC 110/220 V adapter.

15 mm: MT24-25, ISC-200, ISC2-200 · 19 mm (3/4"): SPS-90, PB320EA · 25 mm (1"): SPS90-3, SCS90P-3, P800-3, Z400, ICP100A, ICP100F, ICP106F, PYS-E, PYPZ-E, SG95-550A, SG95-550S, SG95-650S · 32 mm (1.25"): SCS100P-3, SG120B-1.1, SG120B-1.5 · 51 mm (2"): ICP102-50.

Suction lift: ICP100F 8 m; ICP106F 9 m; Z400 9 m; PB320EA 6 m; SCS90P-3 / SCS100P-3 / P800-3 7 m; SPS-90 / SPS90-3 / ICP100A 7 m. Not stated for SG95.

P800/1500 is a permanent magnet motor only, for pump manufacturers. See D group.

What to check before ordering

Duty point · water source · water quality · voltage · pipe size · environment · quantity/port.

Next step

Send the duty point and get a model recommendation

Share the required flow and head, the water uses on site, the voltage and frequency, and the order quantity. The export team will confirm the boosting level, the model, the power setting and the matching documents.

Request B2B Quote
Phone / WhatsApp
+86 178 0591 6566

Cookies: essential storage keeps the site working. Analytics cookies are set only after you click Accept. If you decline, no analytics cookies are set. Cookie Notice